Hardware installation, Connect the power and ground – Comtrol ES8508 Series User Guide User Manual

Page 9

Advertising
background image

RocketLinx ES8508 Series User Guide: 2000575 Rev. A

Hardware Installation - 9

Hardware Installation

You can use the following subsections to install the RocketLinx ES8508 Series:

Connect the Power and Ground

Connect the Digital Input and Relay Outputs

on Page 10

Mount the ES8508

on Page 11

Connect the Ethernet Ports

on Page 12

Connect the Fiber Port (ES8508F)

on Page 13

LED Descriptions

on Page 14

Panel Layout

on Page 15

Reset Button

on Page 16

Connect the Power and Ground

You can use the following procedure to connect power and the ground to the ES8508.

1.

Connect the DC power inputs.

a.

Insert positive and negative wires (12-24AWG) into the PW+ and PW- contacts.

Note: Power should be disconnected from the power supply before connecting it to the switch.

Otherwise, your screw driver blade can inadvertently short your terminal connections to the
grounded enclosure.

AC Power Input

AC Power Input

Power Supply

10 - 60VDC

(UL Listed)

Power Supply

10 - 60VDC

(UL Listed)

V+

V-

V+

V-

12 - 24AWG Wire

12 - 24AWG Wire

Wiring Positive Power Supplies

Positive and negative power system inputs are both accepted, but
PW1 and PW2 must be in the same mode.

Advertising