Mount the es8509-xt – Comtrol ES8509-XT User Manual

Page 11

Advertising
background image

RocketLinx ES8509-XT User Guide: 2000557 Rev. C

Mount the ES8509-XT - 11

Hardware Installation

Digital output relay contacts are energized (open) for normal operation and close for fault conditions. The
digital output relay contacts support up to 1A at 30VDC. Do not apply voltage and current higher than the
specifications.

1.

Insert the positive and negative wires (12-24 AWG) into V+ and V-.

2.

Tighten the wire-clamp screws to prevent the wires from coming loose.

Mount the ES8509-XT

You can use the following procedure to mount the ES8509-XT on a DIN rail or on the wall.

The DIN rail clip is already attached to the ES8509-XT. If the DIN rail clip is not screwed onto the ES8509-
XT, follow the instructions and the figure below to attach DIN rail clip to the ES8509-XT.

1.

If necessary, use the screws to attach DIN rail clip to the rear
panel of the ES8509-XT. (To remove DIN rail clip, reverse Step 1.)

2.

Insert the upper end of DIN rail clip into the back of DIN rail
track from its upper side.

3.

Lightly push the bottom of DIN rail clip into the track.

4.

Verify that the DIN rail clip is tightly attached on the track.

5.

To remove the ES8509-XT from the track, reverse the steps above.

DIN Rail Mounting

Advertising