Hardware Installation

You can use the following subsections to install the RocketLinx ES8509-XT:

Connect the Power and Ground

Connect the Digital Input and Relay Output

on Page 10

Mount the ES8509-XT

on Page 11

Connect the Ethernet Ports

on Page 13

Connect SFP Transceivers (Combo Ports 1-5)

on Page 13

LED Descriptions

on Page 14

Panel Layout

on Page 15

Reset Button

on Page 15

Connect the Power and Ground

You can use the following procedure to connect power and the ground to the ES8509-XT.

1.

Connect the DC power inputs.

a.

Insert positive and negative wires (12-24AWG) into the PWR+ and PWR- contacts.

Note: Power should be disconnected from the power supply before connecting it to the switch.

Otherwise, your screw driver blade can inadvertently short your terminal connections to the
grounded enclosure.

AC Power Input

AC Power Input

Power Supply

10

.5

- 60VDC

(UL Listed)

Power Supply

10

.5

- 60VDC

(UL Listed)

V-

V+

V-

V+

12 - 24AWG Wire

12 - 24AWG Wire

Wiring Power Supplies

Positive and negative power system inputs are both accepted, but PW1 and
PW2 must be applied in the same mode.