Comtrol ES8509-XT User Manual
Page 149
RocketLinx ES8509-XT User Guide: 2000557 Rev. C
Port Configuration (CLI) - 149
Configuration Using the Command Line Interface (CLI)
Port Control (continued)
Port Control
– Flow
Control
Switch(config-if)# flowcontrol on
Flowcontrol on for port 1 set ok!
Switch(config-if)# flowcontrol off
Flowcontrol off for port 1 set ok!
Port Status
Port Status
Switch# show interface gi1
Interface gigabitethernet1
Administrative Status : Enable
Operating Status : Connected
Duplex : Full
Speed : 100
Flow Control :off
Default Port VLAN ID: 1
Ingress Filtering : Disabled
Acceptable Frame Type : All
Port Security : Disabled
Auto Negotiation : Disable
Loopback Mode : None
STP Status: forwarding
Default CoS Value for untagged packets is 0.
Mdix mode is Disable.
Medium mode is Copper.
Switch# show sfp ddm
show SFP DDM information
Port 8
Temperature:N/A
Tx power:N/A
Rx power:N/A
Port 9
Temperature:64.00 C <range :0.0-80.00>
Tx power:-6.0 dBm <range : -9.0 - -4.0>
Rx power:-30.0 dBm <range: -30.0 - -4.0>
Note: Administrative Status -> Port state of the port. Operating status -> Current status of the
port. Duplex -> Duplex mode of the port. Speed -> Speed mode of the port. Flow control -
> Flow Control status of the port.