MIDI Implementation

F7H

BOX (End oi Exclusive Message)

If the device ID on the message was as same as that of the receiving device or 7FH, the VS-

S90 resets all communication channels related svith MMC.

When powered on the VS-890 transmits as the device ID 7FH.

•WRITE

Status

FOH

Byte

FOH

7FH

Dev

06H

40H

ccH

ddH

eeH

ffH

F7H

Data Bytes

7FH,Dev,06H.40H.

ccaddH,eeH„,ffH,„

Status

F7H

Description

Status of Exclusive Message

Universal System Exclusive Message Realtime Header

Device ID (or 7FH)

MMC Command Message

WRITE

Information Bytes follows the command

The name of the writable information Field

Information Field Format

Field names and data

EOX (End of Exclusive Message)

if the device

ID

on the message was as same as that of the receiving device or 7FH the

VS-

890

writes the data tn the specified information field.

The VS-890 does not transmit the message.

•MASKED WRITE

Status

FOH

Byte

FOH

7FH

Dev

06H

41H

04H

ddH

eeH

ffH

SgH

F7H

Data Bytes

7m,Dev,06H.41H.04H,

ddHeeHTfH.gg

Status

F7H

DescripUon

Status of Exclusive Message

Universal

System

Exclusive

Message

Realtime

Header

Device ID (or 7FH)

M.MC Command Message

M.ASKED WRITE

Number of Bytes follows the command

The name of the masked type writable Information Field

Byte number to write in the Bit Map

location of the bit map bvtc to change

New’ data to w’rite to the specified bit map byte

EOX (End of Exclusive Message)

If the device ID on the message was as same as that of the receiving device or 7FK the VS-

890 writes the data to the specified bit map l^tc.

The VS-890 does not transmit the message.

•LOCATE (MCP)

OFormal 1 - LOCATE [l/F]

Status

FOH

Bvte

FOH

7FH

Dev

06H

44H

02H

ООН

nnH

F7H

PalflJyles

7FH.Dev,06H,44H.02H,O0H.nnH

Status

F7H

Description

Status of Exclusive Message

Universal System Exclusive Message Realtime Header

Device ID (or 7FH)

MMC Command Message

LOCATE (MCP)

Number oI Bytes

"i/F" sub command

Information Field (OSH, 09H, OAH, OBH, OCH, ODH, OEH, OFH)

EOX (End of Exclusive Messogc)

If the device ID on the message was as same as that of the receiving device or 7FH, the VS-

690 locates the selected time location stored to the specified information field.

The VS-890 does not transmit the message.

OFonnat 2 - LOCATE [TARGET]

Status

FOH

DatiT Bvles

Status

7FH,Dev,06H,44H,06H,01

H,

F7H

hrH,mnH,scH,frH,ffH

Byte

Description

FOH

Status of Exclusive Message

7FH

Universal System Exclusive Message Realtime Header

Dev

Device ID (or 7FH)

06H

MMC Command Message

44H

L(X:

a

TE(MCP)

06H

Number of Bytes

01H

TARGET'sub rommand

hrH, mnH. scH, frH, ffH

Standard Time with Sub Frame

F7H

EOX (End of Exclusive Message)

If the device ID on the message was as same as that of the receiving device or 7FH, the VS-

890 locates the specified time location received from the command.

if the efficient locate switch ILOC?) or MarLer switch |PREVTOUS|, (NEXT) is pi«sed, the

VS-890 transmits as the device ID 7FH.

•MOVE

Status

FOH

ËylÊ

FOH

7FH

Dev

Ü6H

4CH

02H

ddH

ssH

F7H

Data Bytes

Slat»»

7FH,Dev,06H,4CH,02H,ddH,s5H

F7H

Description

Status of Exclusive Message

Universal

System

Exclusive

Message

Realtime

Header

Device ID (or 7FH)

MMC Command Message

MOVE

Number of Bytes

Name of the Efficient Destination Information Field

{08H,09H.0AH,0BH.0CH,0DH,0EH,0FH)

Name of the Efficient Source Information Field (OtH)

EOX (End of Exclusive Message)

If the device ID on the nussage was as same as that of the receiving device or 7FH, the VS-

890 transfers the data on the selected source information field to the destination Information

Field, If the name of both information fields is efficient.

The VS-890 does not transmit the message.

•The efficient Information Field

The followings are the efficient Information Field on the VS-890.

The name of the efficient destination Information Field :

01H SELECTED TIME CODE

OSH CPO / LOCATE POINTT

09HGP1

OAH GP2

0BHCP3

0CHGP4

ODH CP5

0EHGP6

OFH CP7

4FH TRACK RECORD READY