Constant Duty Cycle
This field defines the duty cycle high time when using the constant duty output type
with a smart igniter. For the EB023 smart igniter the duty cycle high time is 70% with
a corresponding 30% low time.
NOTE:
Now that the ignition set-up is correct the ignition system may be connected to
the ECU. Be sure that the ECU is reset (by turning the key “off” then “on”)
before you connect the ignition system to be sure that the ECU has enabled any
changes made to the set-up.