Chapter 11 digital outputs & pwm outputs – Haltech E6GMX User Manual

Page 77

Advertising
background image

E6GMX Manual

77

CHAPTER 11

DIGITAL OUTPUTS & PWM OUTPUTS


The digital outputs and PWM outputs can be programmed to operate a wide variety of
functions. Some of the functions have restrictions to their operation.

Below is a table showing the ECU’s configurable outputs and their factory information.

Output Information

ECU Output

Factory feature

Pin

Digital Out 1

TCC

A7

Digital Out 2

Thermo fan

C1

PWM Out 1

A/C Control

C2

PWM Out 2

4

th

Gear

C7

PWM Out 3

Spare

F2

PWM Out 4

Spare

F4

Auxiliary Out (Aux Out)

Bypass

D5


The functions and their restrictions are described in the table below:

Output Description

Digital Out 1–2

PWM 1 – 4

Max #

Turbo Wastegate

N/A

2

Bypass Air Control (BAC)

N/A

1

Dual Intake Valve

Unrestricted

Torque Converter Control

1

Thermofan

Unrestricted

Intercooler Fan

Unrestricted

Shift Light

Unrestricted

Aux Fuel Pump

Unrestricted

Stall Saver

1

Staging Signal

Unrestricted

Turbo Timer

1

NOS Switch

1

Anti-Lag Switch

1

BAC2

N/A

PWM 3 & 4

1

BAC2/BAC Slave

N/A

PWM 3 & 4

1

TPS Switch

Unrestricted


For installation information regarding any hardware associated with the described output
functions refer to CHAPTER 1 Haltech ECU Installation, p11.
Each individual function and its parameters are described below.