Page 1

N

eo

T

herm

Boilers and Water heaters

Section 1 -

GENERAL INFORMATION

WARNING

NeoTherm units

must be installed in accordance

with the procedures detailed in this manual, or the

LAARS Heating Systems warranty will be voided.

The installation must conform to the requirements

of the local jurisdiction having authority, and, in the

United States, to the latest edition of the National

Fuel Gas Code, ANSI Z223.1/NFPA54. In Canada,

the installation must conform to the latest edition

of CSA B149.1 Natural Gas and Propane Gas

Installation Code, and/or local codes. Where required

by the authority having jurisdiction, the installation

of NeoTherm boilers must conform to the Standard

for Controls and Safety Devices for Automatically

Fired Boilers, ANSI/ASME CSD-1. Any modifications

to the boiler, its gas controls, or wiring may void the

warranty. If field conditions require modifications,

consult the factory representative before initiating

such modifications.

1.1 Introduction

This manual provides information necessary for the

installation, operation, and maintenance of LAARS Heating

Systems NeoTherm appliances. Read it carefully before

starting the installation.
All application and installation procedures should be reviewed

completely before proceeding with the installation. Consult

the LAARS Heating Systems factory, or local factory

representative, with any problems or questions regarding

this equipment. Experience has shown that most operating

problems are caused by improper installation.
NeoTherm is protected against over pressurization. A

pressure relief valve is included with each NeoTherm. Some

NeoTherms may require that the PRV be installed prior to

filling the system. Refer to Figures 1-7 for PRV locations.

DANGER

The inlet gas pressure to the appliance must not

exceed 13” W.C. (3.2kPa).

All installations must be made in accordance with 1)

American National Standard Z223.1/NFPA54-Latest Edition

“National Fuel Gas Code” or 2) CSA B149.1 “Natural Gas

and Propane Installation Code” and with the requirement of

the local utility or other authorities having jurisdiction. Such

applicable requirements take precedence over the general

instructions contained herein.
All electrical wiring is to be done in accordance with the local

codes, or in the absence of local codes, with: 1) The National

Electrical Code ANSI/NFPA No. 70-latest Edition, or 2)

CSA STD. C22.1 “Canadian Electrical Code - Part 1”. This

appliance must be electrically grounded in accordance with

these codes.

1.2 Model Identification

Consult the rating plate on the unit. The following information

describes the model number structure.

(1-2)

Model Series Designation

N T = NeoTherm

(3)

Usage

H = Hydronic

V = Volume Water

(4-6)

Size

0 8 0 = 80,000 BTU/hr input

1 0 5 = 105,000 BTU/hr input

1 5 0 = 150,000 BTU/hr input

1 9 9 = 199,000 BTU/hr input

2 1 0 = 210,000 BTU/hr input

2 8 5 = 285,000 BTU/hr input

3 9 9 = 399,000 BTU/hr input

5 0 0 = 500,000 BTU/hr input

6 0 0 = 600,000 BTU/hr input

7 5 0 = 750,000 BTU/hr input

8 5 0 = 850,000 BTU/hr input

(7)

Fuel

N = Natural Gas

P = LP Gas

(8)

Options Code

X = Standard Unit

J = CSD-1, FM, GAP, IL Code

(size 500-850 only)

(9)

Pump Options

N = Pump included

(80-500 only)

X = No pump

(configuration available for all sizes)

(10)

Revision

3 = Third version

1

2

3

4

5 6

7

8

9

10

11

SERIES

N T

USAGE

H - HYDRONIC
V - VOLUME

WATER

SIZE

MBTU/h

0 8 0

1 0 5

1 5 0

1 9 9

2 1 0

2 8 5

3 9 9

5 0 0

6 0 0

7 5 0

8 5 0

FUEL

N - NATURAL
P - PROPANE

OPTIONS CODE

X - STANDARD
J - CSD-1,

FM, GAP,

IL

(500-850 only)

PUMP OPTIONS

N - PUMP INCL.

(80-500 only)

X - NO PUMP

REVISION

3 - THIRD

REG DESIGNATION

Model Nomenclature

B

3

N T

B - INTERNAL USE

NTH only

NTH only

NTV only

NTH only

Advertising