5 rmon statistics, Rmon statistics – Compex Systems SGX3226 User Manual

Page 62

Advertising
background image

Chapter 7

Advanced Configuration for Compex SGX3226

52

1. Select SNMP Config from the Command window and enabled the SNMP state.

2. Type in either “Public” or “Private” for both Read-only Community String and

Read-Write Community String.

3. Choose the Trap Setting from 1 to 8 and enter the IP Address and Subnet

Mask correctly.

4. From the State field, select either “disable” or “enable”.

After clicking Apply button, the changes will appear on that particular data row. To
save your configuration, hit Save button.

7.5

RMON Statistics

Remote monitoring (RMON) is a standard monitoring specification that enables
various network monitors and console systems to exchange network-monitoring data.
RMON provides
network administrators
with more freedom in
selecting network-
monitoring probes and
consoles with features
that meet their
particular networking
needs.

1. Select

RMON

Statistics from the
Command
window.








Advertising