Compex Systems SGX3226 User Manual

Page 86

Advertising
background image

Appendix I

Panel Views and Descriptions

76

Features

Status and Indication

5 Redundant

Power

Socket

Additional Power Socket (Optional). With this RPS,
Compex SGX3226 still able to operate even Primary Power
Supply is down.

6

Reset Button

By pushing the reset button once,
• The switch will clear all previous temporary error

• P.O.S.T. will activate self-diagnostic program to check

any error.

• Switch would be re-configured with settings stored in

non-volatile flash memory.

7

Mute Button

To toggle the On or Off Switch of the Alarm Buzzer

Steady Green

Normal Operation

8

System Status LEDs

Steady Red

POST is running Self-diagnostic after reset
or power up

Steady

Green Power supply is working in normal

condition.

9 Power

LED

Steady Red

• Power supply is faulty.

• Power supply fault occurs.

Steady Green

Primary power supply is working and RPS
is in standby mode.

Steady Red

Primary power supply is faulty and RPS is
in working condition.

When the primary power resume its
electrical supply, RPS LED will still
remains Steady Red unless you reboot
your switch, then RPS LED will turn to
Steady Green.

10

Redundant PS LED

Off

Both primary power supply and RPS
turned off.




Advertising