PROHEAT INSTALLATION & SERVICE

6-6

Figure 6-9

Nozzle Components

CLEAN NOZZLE

BLOW THIS DIRECTION
WHEN USING
COMPRESSED AIR.

TORQUE TO
30±3 IN/LBS
(3.4±0.3 Nm)

HOLD
UPRIGHT TO
ASSEMBLE

REPLACE COMPRESSOR AIR FILTER

• Replace inlet air filter annually or more often

if dusty conditions are encountered.

TORQUE TO 50±5 IN/LBS (5.6±0.7 Nm)

• Remove and install Nozzle as shown on page 5-12.

Torque to 150±10 in/lbs (17±1.1 Nm).

• To properly clean the nozzle use electrical

contact cleaner or warm soapy water.

This will wash any dirt out and leave

no residue. When using compressed

air, blow into the nozzle orifice

from the head end.

Figure 6-10

Compressor Air Filter

6.2.10

6.2.9