Ser vice bulletin, If reading is above 10 psi, Notice – Proheat X45–School Bus User Manual

Page 117

Advertising
background image

© 1995 Marine Canada Acquisition Inc. DBA SEASTAR SOLUTIONS 3831 No. 6 Road, Richmond, B.C. Canada V6V 1P6

Tel: 604.270.6899

Web: www.proheat.com

SER VICE BULLETIN

Copy Part# SB0062, Rev. A, 09/2011

Page 2 of 6

5. Install test gauge PK0060 on fuel pump outlet.

6. Switch the PROHEAT on and read the fuel pressure on test gauge.

A reading of 5 – 10 PSI is normal and no fur ther action is required.

NOTICE

Calibrate gauge before each use see

www.proheat.com/PDFs/990614.pdf

for more information.

5

TEST GUAGE

PK0060K

Figure C.

1. Locate the pressure relief valve cap and remove with a slot

screwdriver. Be careful not to lose any of the internal

components that may fall out.

If reading is ABOVE 10 PSI

Figure D.

CAP

BRASS
BALL
GUIDE

BALL
BEARING

SPRING

O-RING

RELIEF

VALVE

ASSEMBLY

FUEL PUMP

COMPRESSOR

Advertising