Proheat X45–School Bus User Manual

Page 93

Advertising
background image

PROHEAT INSTALLATION & SERVICE

5-36

Fuse Blown Test Procedure

with Power Connected and

PROHEAT Switched “OFF”

Check for correct battery polarity

Replace PCM

Reconnect Internal Wire Harness

(18 Pin Connector)

Yes

No

Remove Fuse

Replace Fuse

(15 amp only)

Does

Fuse

Blow?

Replace

Internal

Wire Harness

Reconnect Components

One at a time

Yes

No

Does

Fuse

Blow?

Check Component as per

Troubleshooting Guide

Component OK

Yes

No

Does

Fuse

Blow?

Disconnect all components from

Internal Wire Harness

(10 Connections) (See NOTE)

Reconnect Switch Harness

Yes

No

Does

Fuse

Blow?

Check Switch Harness

and Connections

for Short Circuit

Harness OK

Yes

No

Does

Fuse

Blow?

Disconnect from PCM:

• Internal Wire Harness

(18 Pin Connector)

• Switch Harness

NOTE: Ensure positive wire from

the PCM to the ignition coil

does not ground.

NOTE: A short circuit in the sleeper

fan outlet and hour meter

(auxiliary output) harness

will not blow the fuse. An

error will be indicated on

the PCM. This will not shut

the heater down.

Figure 5-28

Blown Fuse Test Procedure Flow Chart

Advertising
This manual is related to the following products: