SECTION 5. TROUBLESHOOTING & REPAIR

TROUBLESHOOTING
AND REPAIR

5.0

Problems with the PROHEAT and its operation will be indicated in two ways:

1.

PROHEAT Diagnostic Faults indicated by means of a flashing diagnostic code

on an indicator light on the switch, Timer red manual light or OEM indicator

light (installation options). See Example Proheat Behavior Error on page 5-2.

2.

Operational problems may not be identified with a flashing diagnostic code

(e.g. blown fuse, smoking exhaust, backfiring or low heat output. Go to

page 5-34 to page 5-37.)

TROUBLESHOOTING A PROBLEM

Locate the PROHEAT, remove the enclosure lid if equipped and visually check

for any problems with wiring harnesses, fuel leaks, coolant leaks, exhaust

pipe damage and environmental conditions.

Inspect Proheat Control Module (PCM) display for error code. If PCM display is

difficult to view, determine the blink code on the switch, Timer red manual

light or OEM indicator light (installation options).

If no code is indicated, turn the PROHEAT off and then on again using the

existing operational switches, timer or a PROHEAT remote start switch

(PROHEAT P/N 952925K).

Let the PROHEAT attempt to start and/or operate. Observe the operation.

NOTE: The PROHEAT will always attempt to start twice, as long as the coolant

temperature is below 150°F (65°C). If a fault is detected it will shut down, go

through a Cool Down (Purge) and attempt a second start. After both attempts

to start or operate, the PCM will display a code and the switch, Timer red

manual light or OEM indicator (installation options) will blink the same code.

After two consecutive start attempts, the PROHEAT will not attempt to

start again and goes into a hold state. In the hold state the switch, Timer

red manual light or OEM indicator light (installation options) will blink the

error code(s) continuously. The PROHEAT will try again once the switch is

turned "OFF" and then "ON" again.

If the indicator light flashes, count the number of flashes and refer to

the troubleshooting diagnostic code description for that number on the

following pages.

If the PROHEAT runs but is not performing or operating correctly, consult

the Operational Problems, Section 5.3 on page 5-37.

Troubleshooting and Repair Tools Required

Remote Start Switch (PROHEAT P/N 952925K)

Allows the service technician to work at the PROHEAT. Isolates the PROHEAT

from the existing vehicle system controls and comes with a built-in indicator light.

Digital Air Compressor Test Gauge (PROHEAT P/N PK0037)

Allows the service technician to check compressor pressure in order to

ensure for correct fuel delivery. (Note The analog Air pressure gauge

PK0060 can also be used.)

STEP 1

STEP 2

STEP 3

STEP 4

5-1

5.0.1

NOTICE

Troubleshooting and repair is to be

performed by Authorized Proheat

Dealers.

Figure 5-1

Troubleshooting Tools.

Advertising
This manual is related to the following products: