SECTION 5. TROUBLESHOOTING & REPAIR

5-7

Fuel System – Step 2

Check:

Regulator

a)

For damage, contamination and mechanical operation.

Test Procedure — Vent Hole Regulator Style:

a)

Disconnect the fuel line at the nozzle fuel inlet fitting and place

in a container.

b)

Inspect vent hole to ensure that it is not plugged.

c)

Start the heater. No fuel should be exiting the outlet of the

regulator.

If fuel is leaking from the outlet, replace fuel regulator.

Test Procedure — Capped Style:

a)

Remove fuel line that goes from the outlet of the regulator to

the nozzle.

b)

Start the heater. No fuel should be exiting the outlet of the

regulator.

If fuel is leaking from the outlet, replace the fuel regulator.

c)

Install clear plastic hose that replaces the hose removed.

d)

Start the heater. Fuel should start to flow out of the regulator

and up to the nozzle.

If the regulator does not operate as described in d), replace the

regulator.

PLACE THIS LINE IN A
CONTAINER OF FUEL

MAINTAIN FUEL LEVEL
AT CENTRE OF THE
REGULATOR

REMOVE FUEL LINE
FROM REGULATOR

Figure 5-4

Eliminating Fuel Pump and Regulator from system.

Advertising