The electrode is located near the nozzle just out of the air/fuel mixture path.

During the ignition sequence the spark jumps the gap between the electrode and

the combustion tube, igniting the air/fuel mixture. Spark duration is 60 seconds.

Measures coolant temperature at the outlet port of the heat exchanger.

Protects the heater from damage should it be operated without coolant. The

overheat breaker monitors the surface temperature of the heat exchanger casting.

When the temperature reaches 286˚F (141˚C) the breaker “trips out.” This shuts

off the power to the air compressor—extinguishing the flame. The breaker can

be reset by pushing down on the red button (located under the rubber cap).

Photo-electrically measures the intensity of the flame. It is the flame sensor

that signals to the PCM that the air/fuel mixture is burning properly.

Is used to switch the heater “ON” and “OFF.” It has an indicator lamp that

displays a red light when switched “ON.” A flashing red light indicates a heater

diagnostic code and one of the LEDs on the PCM diagnostic display will be lit.

(See page 5-3 for details.)

Is used to switch the heater “ON” and “OFF.” This can be done manually or by

a preset time and day. It has an indicator lamp that displays a red light when

switched or timed “ON.” A flashing red light indicates a heater diagnostic code

and one of the LEDs on the PCM diagnostic display will be lit. (See page 5-3

for details.)

On Sleeper Fan 12 V models (see page 4-2), the Proheat Control Module is

equipped with a 3 A limited output. It is used to drive fans or other equipment

as determined by the installation (see page 3-1). The output is ON 60 seconds

after switch ON. In addition, it is also ON when there is a functional error (see

page 5-1 for details).

12. Coolant Temperature

Sensor

11. Ignition Electrode

13. Overheat Breaker

Sensor

14. Flame Sensor

15. On/Off Switch

16. 7 Day Timer

17. Sleeper Fan

(only output connector

shown)

T-II

CLOCK

TIMER ID LIGHT
(GREEN)

INDICATOR LIGHT
(RED)

TIMER SET
BUTTON

MANUAL
BUTTON

Figure 4-5

7 Day Timer

Figure 4-4

ON/OFF Switch

Indicator Light

Located in the Toggle

4-4

PROHEAT INSTALLATION & SERVICE