13 check air pressure, Replacement parts, Operation test – Proheat X45–School Bus User Manual

Page 103

Advertising
background image

6-8

PROHEAT INSTALLATION & SERVICE

PART #

QTY

DESCRIPTION

825730K

1

Air Filter, X45.

880035K

1

Fuel Filter, X45.

PART #

QTY

DESCRIPTION

PK0094

1

X45 Fall Service Kit

includes:

1 x Air Filter

1 x Fuel Filter

2 x O-Ring

PK0069

1

X45 Major Service Kit

1 x Electrode

1 x Nozzle

1 x Regulator

1 x Flame Sensor

1 x Ignition Lead

1 x Air Filter

1 x Fuel Filter

2 x O-Ring

Replacement Parts

CHECK MODES OF OPERATION – SWITCH, TIMER OR
OEM SIGNALS

• Check to see that the modes operate as described on page 4-5 to page 4-7.

Operation Test

• Run the system for at least 15 minutes or until the heater cycles “OFF” and

then “ON” again.

• Alternate the thermostat for the sleeper heater (if connected) between the

lowest and highest settings to ensure that the sleeper heater fan cycles

“ON”and “OFF”.

6.2.13

CHECK AIR PRESSURE

• Refer to Air Compressor pressure test procedure on page 5-9.

6.2.12

Figure 6-13

Air Compressor pressure test procedure

HOSE TO

NOZZLE AIR

INLET

DIGITAL

MANOMETER

PK0037

HOSE FROM COMPRESSOR

Advertising
This manual is related to the following products: