Product update bulletin, Old pcm display new pcm display – Proheat X45–School Bus User Manual

Page 113

Advertising
background image

© 2009 Marine Canada Acquisition Inc. DBA SEASTAR SOLUTIONS 3831 No. 6 Road, Richmond, B.C. Canada V6V 1P6

Tel: 604.270.6899

Web: www.proheat.com

PRODUCT UPDATE BULLETIN

Copy Part# PB0034, Rev. B, 04/2009

Page 2 of 3

1

100 % Backward Compatible

• G-III PCM works with existing heaters and wiring harnesses.

2

CANbus Communication and new Serial Port Location

• The new communication port provides CANbus SAE J-1939 communication.

• Relocated serial port allows Datalink connection without disconnecting

the switch input.

• New communication port requires the G-III controller Proheat Data Link

Kit PK0053-3. The G-II download cable kit PK0053-2 (download cable

and software) will not work with the G-III controller.

3

New 2x7 Segment LED

• The 2x7 segment LED provides improved communication of operational

states and error messages.

• Figure 2: Original G-II PCM display with single LED lamps and new G-III PCM

display with 2x7 segment LEDs.

Figure 3: Original G-II PCM code numbers still apply. For example,

Diagnostic Code LED associated with 12 Blower on the original PCM

display will light up as the number 12 on the new display. In addition,

the G-III controller indicator switch lamp will blink 12 times like the G-II

controller does.

Figure 3: Also illustrated is the “ON” indicator meaning the heater is

powered in the normal or standby state and “Pu” indicator showing the

heater is in the Cool Down (Purge) state.

X45 ONLY: A new error code, 14, has been added to indicate a short

circuit on the hour meter (auxiliary output) harness. For this error code,

the indicator switch lamp will blink 14 times as well.

Figure 2: Comparison of the original G-II PCM to the new G-III PCM display.