SECTION 5. TROUBLESHOOTING & REPAIR

5-9

Fuel System – Step 4

Check:

Air Compressor

a)

Air compressor pressure and operation

Test Procedure — Air Compressor pressure:

a)

Run heater until warm to the touch. This ensures the heater

components are up to normal operating temperature.

b)

Switch heater off.

c)

Install PK0037 Digital Manometer (or a calibrated PK0060

Analog Air pressure gauge) in-line as shown in Figure 5-6.

HOSE TO

NOZZLE AIR

INLET

DIGITAL

MANOMETER

PK0037

HOSE FROM COMPRESSOR

Figure 5-6

d)

Locate the rubber boot on the positive end of the ignition coil

and peel it back to expose the positive terminal.

e)

Select the DC Volts range of a multimeter and connect as per

Figure B. The positive lead of the multimeter should be

attached to the positive coil lead. The negative lead of the

multimeter should be attached to the heater chassis at the

PROHEAT ground boss.

f)

With the heater running in full output (flame on and ignition is

off) read the voltage and refer to the 12 or 24 volt chart (Figure

5-8 and Figure 5-9) for the correct Air Pressure Reading.

g)

The reading must be within the range of the shaded area as

shown in Figure 5-8 and Figure 5-9.

NOTICE

If using PK0060, Analog Air pressure

gauge, calibrate gauge before each

use refer to:

www.proheat.com/PDFs/990614.pdf

NOTICE

Altitude Correction is needed above

3000 Feet (see inset on charts).

DO NOT adjust air pressure when

above 6000 Feet.

NOTICE

Remove Pressure Gauge when finished

with measuring & setting procedure.

WARNING

Shock hazard due to high secondary

coil voltage.

Advertising