Gs (e pl ph fn a fn = 12 – CITIZEN CT-S300 User Manual

Page 112

Advertising
background image

— 107 —

fn = 12: Function 12 Sending the Set Communication Conditions of

Serial Interface

GS (E pL pH fn a fn = 12

[Code]

<1d>H<28>H<45>pL pH fn a

[Range]

(pL + pH

× 256) = 2 (pL = 2, pH = 0)

fn = 12

1 a 4 (Does not send in other than specified range)

[Outline]

Sends communication conditions of serial interface specified by “a”.

• a = 1: Setting baud rate

Hex.

No. of Data

Header

37H

1

ID

33H

1

Kind of communication conditions (a)

31H (“1”) ~ 34H (“4”)

1

Separation number

1FH

1

Set value

30H ~ 39H

1 ~ 6

NULL

00H

1

Set value

• a = 1: At specification of baud rate

Baud Rate

d1

d2

d3

d4

d5

d6

2400

50 (“2”)

52 (“4”)

48 (“0”)

48 (“0”)

4800

52 (“4”)

56 (“8”)

48 (“0”)

48 (“0”)

9600

57 (“9”)

54 (“6”)

48 (“0”)

48 (“0”)

19200

49 (“1”)

57 (“9”)

50 (“2”)

48 (“0”)

48 (“0”)

38400

51 (“3”)

56 (“8”)

52 (“4”)

48 (“0”)

48 (“0”)

• a = 2: At specification of parity

d1

Parity Setting

48

No parity

49

Odd parity

50

Even parity

d1

Flow Control

48

DSR/DTR

49

XON/XOFF

• a = 3: At specification of flow control

d1

Setting Data Length

48

7-bit length

49

8-bit length

• a = 4: Setting to specified data length

Advertising