Gs c0 m n – CITIZEN CT-S300 User Manual

Page 87

Advertising
background image

— 82 —

GS C0 m n

[Function]

Setting the numbering print mode

[Code]

<1D>H<43>H<30>H<m><n>

[Range]

0 m 5

0 n 2

[Outline]

This command sets the numbering (serial number counter) print mode.

“m” denotes the number of print columns.

m = 0

Prints the columns indicated by numeral. In this case, “n” has no
meaning.

m = 1 to 5

Indicates the maximum number of columns to be printed.

Prints the counter in “m” columns.

“n” specifies a printing position within the printing columns.

n = 0

Prints the data right justified. The blank columns are spaced.

n = 1

Prints the data right justified. The blank columns are filled with "0".

n = 2

Prints the data left justified. The right blank will become invalid.

[Caution]

If either “m” or “n” has a value beyond their ranges, that setting will becomes invalid.

[Default]

m = 0 , n = 0

[See Also]

GS C1, GS C2, GS c, GS C;

[Sample Program]

LPRINT CHR$(&H1D);"C0";

*CNT

LPRINT CHR$(0);CHR$(0);

FOR I=1 TO 5

GOUSAB *CNT

LPRINT CHR$(&H1D);"c";

LPRINT CHR$(&H1D);"C0";

NEXT I

LPRINT CHR$(1);CHR$(0);

LPRINT CHR$(&HA);

GOUSAB *CNT

RETURN

LPRINT CHR$(&H1D);"C0";
LPRINT CHR$(3);CHR$(0);
GOUSAB *CNT
LPRINT CHR$(&H1D);"C0";
LPRINT CHR$(3);CHR$(1);
GOUSAB *CNT
LPRINT CHR$(&H1D);"C0";
LPRINT CHR$(3);CHR$(2);
GOUSAB *CNT
END

[Print Results]

12345 <

Counts from 1 to 5 at m = 0 and n = 0.

67890 <

Counts from 6 to 10 at m = 1 and n = 0.

11 12 13 14 15 <

Counts from11 to 15 at m = 3 and n = 0.

0160 170 180 19020 <

Counts from 16 to 20 at m = 3 and n = 1.

21 22 23 24 25 <

Counts from 21 to 25 at m = 3 and n = 2.