DLE DC4 fn m t (Specification of fn = 1)

[Function]

Outputting specified pulse in real-time

[Code]

<10>H<14>H<fn><m><t>

[Range]

fn = 1, 0 m 8, 1 t 8

[Outline]

• A signal specified with “t” is output to the connector pin specified with “m”.

• Set the ON time/OFF time to t

× 100 ms, respectively.

[Caution]

• When receiving a code row coinciding with the code configuring this command,

the same operation as this command takes place and attention by the user is
required.

Example: When corresponding code row is present in bit image data.

• This command must not be used between other command code rows.

Example: This command is used in the bit image data.

• This command is ignored under the following conditions.

• During sending block data

• During output of signal to drawer kick connector

• During occurrence of error

[See Also]

ESC p

m

Connector Pin

0

Pin No. 2 of drawer kick-out connector

1

Pin No. 5 of drawer kick-out connector