Gs i n1l n1h n2l n2h – CITIZEN CT-S300 User Manual

Page 92

Advertising
background image

— 87 —

GS I n1L n1H n2L n2H

[Function]

Setting the Black mark length

[Code]

<1D>H<6C>H<n1L><n1H><n2L><n2H>

[Range]

0 n1L 255 (24 n1L + n1H

× 256 360)

0 n1H 1

8 n2L 30

n2H = 0

[Outline]

Define the specifications (length) of the Black mark used.

n1: Sets the Black mark length

n2: Sets the Black mark gap length

n1 and n2 are specified units of millimeters.

Divide the maximum Black mark length by 256 with the quotient designated as n1L
and the remainder as n2H. Accordingly, the Black mark length available for setting
will be n1L + n2H

× 256.

[Caution]

• If the specified length is outside of Black mark specifications, the default length is

set.

• 360 mm is the maximum Black mark length allowed to define and 24 mm is the

minimum.

• 30 mm is the maximum allowable Black mark gap length to define and 8 mm is the

minimum.

[Default]

The following default values are set when memory switch SW4-1 is set to ON.

n1L = 25

n1H = 0

n2L = 8

n2H = 0

n1

n2

Advertising