4.2. Global Preset Memory Correction

This function simultaneously resets all preset camera panning positions. The deviation of one camera position
is measured, based on which all other positions are globally corrected. When performing this global
correction, use the position on the telescope side whenever possible.

1. Select “PRESET” on the camera menu screen and press the

Set key.
The Preset Settings screen is displayed.

2. Select “READJUST ALL POS” with the joystick and press the

Set key.

3. Enter the camera position number with the numerical keypad,

and press the Set key. The Entered figure is displayed.

4. Press the Set key.

Preset memory correction screen is displayed.

Note
If a number not used for the preset memory setting is entered,
that number is displayed, however the preset memory
correction screen is not displayed. Enter the figures that are
used for the preset memory setting.

5. After adjusting the panning direction with the joystick, press

the Set key.
All preset memory positions can be corrected.

Preset setting screen

M E M O R Y

R E A D J U S T A L L P O S

M E M O R Y R E S E T

M E M O R Y A L L R E S E T

A U T O R E T U R N

H O M E

P R E S E T F R E E Z E

* * *

P O S

N O

O F F

1 P O S

O F F

*

P R E S E T

*