[ Sector Range setting/ clearing ]

1. Select “FIX,” “EACH,” or “CLEAR” on the sector ID setting

screen with the joystick, and press Set key.

1-1 When “FIX” is selected

Tilt the joystick left or right to move the camera direction to
the “North” position, then press the Set key.
Eight directions are automatically set.

Fixed direction setting screen

N O R T H

S E C T O R S E T T I N G

1-2 When “EACH” is selected

The arrow

moves to a number.

(1) Select the sector to be set with the joystick and press the Set

key.

(2) Tilt the joystick left or right to move the camera direction to

the left position of the sector, then press the Set key.
Similarly, with the joystick, move the camera direction to the
right position of the sector, then press the Set key.

( )

L E F T

S E C T O R S E T T I N G

Individual orientation setting screen

Sector setting screen

*

S E C T O R

*

S E C T O R S E T T I N G

F I X

- - - - - - - - - - - - - - - - - - - - - - - - - - -

1 : N O S E T U P

2 : N O S E T U P

3 : N O S E T U P

4 : N O S E T U P

6 : N O S E T U P

5 : N O S E T U P

7 : N O S E T U P

8 : N O S E T U P

1

2

3

4

5

6

7

8

( NE )

( E )

( SE )

( S )

( SW )

( W )

( NW )

( N )

North

1-3 When “CLEAR” is selected

The arrow

moves to a number.

(1) Select the sector to be cleared with the joystick and press the

Set key.

(2) The screen moves to the preset position, then “SECTOR

CLEAR OK?” is displayed. Press the Set key.

( )

Clear screen

S E C T O R C L E A R O K ?