Monitor-related functions, Scan monitor – Toa VS-900 User Manual

Page 41

Advertising
background image

3-13

CHAPTER 3. CONVENIENT FUNCTIONS

[Exceptions]

(1) When the designated receiving station (example: 93) is busy, all succeeding calling parties must wait.

(Even Station 93 is also registered for Busy Call Forwarding, only the first transfer attempt to this station is
made, followed by no further attempts. The waiting stations wait until the line of Station 93 becomes free.)
As soon as Station 93 finishes its conversation, the next calling party is automatically put through to that
station. When the line of the original station (example: 92) is freed while Station 93 is still busy, the calling
party is connected to Station 92 without being transferred.

(2) The designated receiving station (93) can directly call the original station (92) without interference from the

call forwarding function.

(3) The Busy Call Forwarding function is disabled when the designated receiving station has already been

registered for Call Forwarding.

(4) The Busy Call Forwarding function does not interfere with a substation call to a Group Call representative

station that is registered for Busy Call Forwarding. (The group call designation is given priority.)

MONITOR-RELATED FUNCTIONS

7. SCAN MONITOR

7.1. Function

Any master station can scan a designated group of substations for audio monitoring of each substation.
(See the figure on the next page.)

[System pre-programming]

(1) Substations to be monitored (up to 16) can be registered for each master station in system programming.

(2) Monitor interval times of 1 – 99 seconds (in 1 second units) for each master station can be registered in

the system programming.

7.2. Scan Monitor Operation

Step 1. Automatic scanning

Press [ ][2] at the master station.

• Scanning begins and automatically cycles through the substation group in the registered order and

at the registered time interval until manually stopped.

• The number or name of the substation being monitored is displayed on the master station.
• The handset may also be used for monitoring by simply lifting it.

Step 2. Manual scanning

(1) Automatic Scanning Stop & Restart

To continue monitoring a particular substation, press the [0] key to stop automatic monitoring scan
at that station. Pressing the [0] key again will restart the automatic scanning sequence.

(2) Scan FORWARD

Pressing the [#] key advances monitoring by one substation.

(3) Scan BACK

Pressing the [ ] key reverses monitoring by one substation.

(4) Talking to the substation

Press the [PTT] key to talk to the substation.

Step 3. Scan monitor termination

To terminate the Scan Monitor operation, either press the [C] key or replace the master station handset.