3-15

CHAPTER 3. CONVENIENT FUNCTIONS

[System pre-programming]

(1) The number of zone number digits (1 or 2 digits) can be registered in system programming.

Single digit: Zone Nos. 1 – 9
Double digit: Zone Nos. 01 – 19

(2) Substation numbers and selective external public address equipment outputs to be included in each zone

can be registered in the system programming. Up to 1,024 substations and up to 16 selective outputs can
be registered per zone.

Note: Only 1 voice output is made available for paging to external equipment. It is impossible for 2 or

more persons to simultaneously initiate paging.

8.2. Zone Paging Dialing Operation

Step 1. First press [ ][8], and then the desired zone numbers (example: [2] & [3]) followed by [#].

Up to 9 (19) zones can simultaneously be selected.

Step 2. A paging pre-announcement tone is transmitted to the selected zones.

Place a paging call with the handset either off-hook or on-hook.*

1

Step 3. To terminate the broadcast, replace the handset or press the [C] key.*

2

*

1

If using a telephone, lift the handset to place a paging call.

*

2

If using a telephone, replace the handset to terminate the paging call.

[Paging Priority order]

Current zone paging will be interrupted when the following paging or broadcast functions are initiated:

1. Emergency paging
2. Emergency conference
3. External source distribution
4. All-zone paging

Note
Current paging could be suddenly cut off when Emergency Paging, Emergency Conference or External
Source Distribution with higher priority is initiated.