Toa VS-900 User Manual

Page 69

Advertising
background image

5-3

CHAPTER 5. PC-CONTROLLED FUNCTIONS

2.3. Function Setting

(1) Group call setting
Registers the following contents designating the representative master station/telephone.

Contents

Setting Item

Member Station Exchange Number

Member Station line Number

Sets the exchange number (1 – 16) of the master station or telephone.

Sets the Line number (1 – 4) of the master station (telephone).

(2) Call forwarding & time-out settings
Registers the following contents designating the exchange number (1 – 16).

Contents

Setting Item

Call Forwarding

Enable/Disables the Call Forwarding function.

Time-Based Call Forwarding

Enables/Disables the Time-Based Call Forwarding function by its start
and end times.

Time-Based Call Forwarding Start
Time

Sets the hour and minute the call forwarding interval will begin. ( 00:00
– 23:59)

Time-Based Call Forwarding End
Time

Sets the hour and minute the call forwarding interval will end. ( 00:00 –
23:59)

Busy Call Forwarding

Enables/Disables the Busy Call Forwarding function.

No-Answer Call forwarding

Enables/Disables the No-Answer Call forwarding function. If enabled,
calls are transferred when no response is detected within the preset
interval.
Sets the station calling interval (1 – 99 seconds).

Call Time-Out

Enables/Disables the call time-out function. If enabled, calls are
terminated when no response is made within the preset interval.
Sets the station calling interval (1 – 99 minutes).

Conversation Time-Out

Enables/Disables the Conversation Time-Out function. If enabled,
conversations are automatically terminated when the time limit is
reached.
Sets the conversation time limit (10 – 990 seconds).

(3) Scan monitor setting
Registers the following contents designating the master station.

Contents

Setting Item

Monitoring Time

Sets the scan-monitor time interval (1 – 99 seconds).

Monitoring Substation Exchange
Number

Sets the number of the exchange to which the substation is connected
(1 – 16).

Monitoring Substation Line Number Sets the substation equipment number (1 – 64).

Monitoring Substation Number

Sets the substation number.

Monitoring Substation Name

Sets the substation name.

(4) Paging setting
Registers the substations assigned to the zone designating the exchange number (1 – 16).

Contents

Setting Item

Zone Number Digit

Selects the length of the digit to be used to label the paging zone
numbers (1 – 2).

Paging Time-Out

Enables/Disables the Paging Time-Out function.

Zone

Resisters substation numbers (1 – 1024) for each zone.

Sets a Paging time limit (10 – 990 seconds).

Advertising