5 trigger signal exporting, Trigger signal exporting, Figure 4-8: trg io output signal timing – ADLINK PXI-2022 User Manual

Page 41

Advertising
background image

Function Block and Operation Theory

33

4.4.5

Trigger Signal Exporting

The PXI-2020/2022 can export trigger signals to following connec-
tors/bus: SMB TRG IO on front panel, AFI0 on front panel and PXI
Trigger Bus Line 5. The TRG IO on the front panel can also be
programmed to output the trigger signal when the trigger source is
from software trigger, Auxiliary Function Interface, PXI Star Trig-
ger, or PXI Trigger Bus Line 5. The timing characteristic is in Fig-
ure 4-8.

Figure 4-8: TRG IO Output Signal Timing

TRG IO

(Output)

Tw

Tw = 3 TIMEBASE Clocks

Advertising
This manual is related to the following products: