410sx operator’s manual – Ditch Witch 410SX User Manual

Page 117

Advertising
background image

Service - 116

410sx Operator’s Manual

As Needed

Check Batteries

Check batteries as needed. Keep batteries clean
and terminals free of corrosion.

To clean:

1.

Turn battery disconnect switch, if equipped, to
the off position.

2.

Ensure that no ignition sources are near
batteries.

3.

Loosen and remove battery cable clamps
carefully, negative (-) cable first.

4.

Clean cable clamps and terminals to remove
dull glaze.

5.

Check for signs of internal corrosion in cables. Replace battery and/or cables if damaged.

6.

Apply MPG to terminals after cleaning to reduce corrosion.

7.

Connect battery cable clamps, positive (+) cable first.

8.

Tighten any loose connections.

9.

Ensure that battery tiedowns are secure.

10. Turn battery disconnect switch to the on position.

NOTICE: For the 410sx Gas, ONLY USE the following replacement battery: Optima 8004-003
(p/n 215-1165).

Explosion possible. Serious injury or equipment damage could occur.

Follow directions carefully.

To help avoid injury:

Do not create sparks and do not short across battery terminals for any reason.

Do not operate 410sx Gas unit without battery heat shields in place.

t39om074w.eps

Advertising