410sx Operator’s Manual

Controls - 27

Tractor

CMW

2.

Operator presence
switch

Detects when operator is
present.

Press and hold switch before
moving ground drive control
or digging controls out of
neutral.

If switch is released during operation,
alram will sound and engine will die.

3.

Hydraulic fluid
temperature indicator

Lights if hydraulic fluid
overheats.

If light remains on:

Check that engine fan is turning
when engine is running.

Turn off engine and let it cool.

Check hydraulic fluid level.

Check front of hydraulic cooler for
debris.

4.

Check engine /
Malfunction indicator
light

Lights when an engine
problem has been detected.

Lights momentarily when ignition
switch is turned to the ON or START
position.

5.

Engine information
display

Displays status of certain
engine functions: RPM,
engine hours, battery voltage,
oil pressure, coolant
temperature, and engine
diagnostic codes.

See “Engine Diagnostic Codes” on
page 78.

“Engine hours” refers to amount of
time key is on position without engine
running. “Machine Hours” refers to
amount of time engine has been
running above 100 rpm.

Item