10 - user interface quick reference – Dunkirk Q95M-200 Modulating Condensing Boiler User Manual

Page 24

Advertising
background image

24

INFORMATION MODE

Press [MODE] button 2 times from Standby Mode.

Display shows Info until a key is

pressed

Info

Then displays Parameter, Flashing Dot, and Current Status.

1.190

Press and Hold Key(s) in BLACK (1)

Duration Result

Display

[MODE]

[STEP]

[STORE] [+] [-]

Tap

Step to next

parameter

Measured outlet water temperature

(First digit shows 1 and dot flashes) (1)

1.180

(1) Digits after flashing dot show measured outlet temperature.

(2) Digits after flashing dot show -18.

(3) Digits after flashing dot show outside temperature.

(4) Digits after flashing dot show target outlet temperature.

(5) Digits after flashing dot show rate of change in °F per second.

(6) Digits after flashing dot show -32.
NOTE: Display will show A-32 if [STEP] is pressed after “9” appears.

Return water temperature

(First digit shows 2 and dot flashes) (1)

2.150

This function not used

(First digit shows 3 and dot flashes) (2)

3.-18

Outside temperature

(First digit shows 4 and dot flashes) (3)

4. 42

This function not used

(First digit shows 5 and dot flashes) (2)

5.-18

Target outlet water temperature

(First digit shows 6 and dot flashes) (4)

6.190

Outlet water temp. change over time

(First digit shows 7 and dot flashes) (5)

7. 1

Return water temp. change over time

(First digit shows 8 and dot flashes) (5)

8. 1

This function not used

(First digit shows 9 and dot flashes) (6)

9.-32

10 - USER INTERFACE QUICK REFERENCE

Advertising