EXFO MaxTester MAX-610 User Manual

Page 138

Advertising
background image

SmartR™ Features

130

MAX-610

Pair Detective

The previous 2 parameters have 2 modes of operation:

Auto is the default mode upon loading the test page. TDR
automatically optimizes the test parameters and scans each band
individually looking for one Largest Event in each band (if any).
Range and Gain are updated to reflect optimized TDR settings.
Once results are displayed, TDR switches to manual mode. The
test keeps running until you press Start/Stop.

Manual mode allows you set the test parameters to be used as
inputs for the TDR measurements.

Note: If either of the above 2 test parameters are set to Auto, respective

parameter values will be updated by TDR test.

Pulse Width is a non-editable value that is updated dependent on
whether the parameters are set to Auto or manual.

Cable Setup button opens a new page that allows you to set the Cable
Parameters
for the Current Test.

Select Graph button changes to Graph Selected when pressed and
opens a new selection of function keys which allow you to maneuver
the graph as follows:

Cursor - press the left/right arrow keys to decrease/increase the
values by moving the cursor. Press and hold the left/right arrow
keys to accelerate the cursor. Press

to recall the cursor and

place it in the middle of the current x-axis limits.

Zoom references the middle of the x/y axis and not the cursor
position. Press the arrow keys as follows:

Right = x-axis zoom in.

Left = x-axis zoom out.

Up = y-axis zoom in.

Down = y-axis zoom out.

Advertising