Setting Up Copper Tests

MaxTester Copper Test

71

Application Settings

Buzzer

The Buzzer tab allows you to configure values for the
buzzer settings. However, due to the risk of electrical
shocks, the MaxTester detects high voltages on any
pair of leads without user intervention.

Buzzer Threshold Voltage allows you to
configure the hazardous voltage level from 70 to
150 volts.

Hush Time allows you to configure the hush
timeout from 1 to 15 minutes.

Hush Buzzer button mutes the sounding buzzer.

Note: Upon raising the hazardous voltage flag, the MaxTester opens the relays

and you will have to press Start/Stop on the keypad to re initialize the unit.
In case the voltage is still too high, the MaxTester will open the relays once
again preventing any damage to the equipment. If not, the test will start
normally.