Setting Up Copper Tests

MaxTester Copper Test

75

FED Setup

The FED Setup tab displays the following parameters:

FED sets the default FED States for the following
tests to Enabled or Disabled, and is saved as part
of the profile:

Multimeter

Noise

Frequency

Other

When FED is Enabled and you start a test, the
MaxTester will warn you if the FED battery level is low. Select OK to close
the message and run the test.

FED States are displayed in the Current Test line as a numeral on the
right-hand side of the FED icon, for example

. Numerals match the

following states:

0 = FED Open

1 = FED T-R/A-B Shorted

2 = FED Shorted ALL

3 = FED Pass Through/Exchange Connect

4 = FED ID Tone

5 = FED Terminated

6 = FED Crosstalk NEXT

7 = FED Transmit

8 = None