Figure 6.25 die protection bypass screen – LINK Systems OmniLink II Press Automation Control User Manual

Page 136

Advertising
background image

August 30, 2002 Manual Version 1.0

6.31

Section 6.7.3.4 Bypass in Setup Mode and Bypass on Job Recall

Individual channels can be automatically bypassed when the press mode is switched to Setup mode.
This will allow certain channels to be turned off when in press Setup mode.

Also, individual channels can be automatically bypassed for a programmed number of strokes after a job
recall. The number of strokes that the channel will be bypassed is programmable per channel. This
feature allows for sensors in progressive dies to be bypassed for the number of strokes that are required
for the material progression to get to the sensor. For example, a sensor in the fifth stage of a five stage
die will not see material until the fifth stroke. This sensor can be bypassed for four strokes after the job
recall.


Individual channels must be programmed to bypass in Setup mode or to be bypassed for a number of
strokes after a job recall. These items are programmed in the Die Protection Bypass Setup screen. To
display the Die Protection Bypass Setup screen, select BYPASS SETUP softkey in the Die Protection
Screen, Figure 6.22. The Die Protection Bypass Setup screen is shown in Figure 6.25.

Section 6.7.4 Reset


Channel faults must be reset before the issued stop signal is removed. The RESET ERROR softkey on
the Die Protection screen, Figure 6.22, must be used to reset faults.

There are several configurations for the Reset Error softkey availability. This softkey can be configured
to be available at all times. When configured to be available at all times, the Reset will be available to
all operators. Neither the Run/Program key or code access will be required to reset. The Reset Error
softkey can be configured to be available to only personnel who can gain control access to the Die
Protection Reset.

There are two configurations for the number of channels that the RESET ERROR softkey will reset at

Stroke

Mode

Drive

Speed
Stroke
Speed

SPM

SPM

0
0

Order

Counter

SYSTEM STATUS

Counter OFF

DP Bypass
Setup

CHANGE
SETTING

EXIT

0

0

Program/Run Switch

TOP

Production

NEXT

PAGE

Bypass

Job

Module: 1

In

Recall

Setup

Bypass

Ch Description

Mode

Strokes

1

2

3

4

5

6

7

8

Stock Buckle

End of Stock

Part Detector

Feed Complete

Left Front Stripper

Right Front Stripper

Left Rear Stripper

Right Rear Stripper

No

No

Yes

Yes

No

No

No

No

0

0

3

2

0

0

0

0

Die Protection Bypass Setup

Help

If “Bypass in Setup Mode” is “Yes” AND SETUP/PRODUCTION
MODE INFO IS AVAILABLE, then the die protection channel
will be bypassed in setup mode.

Figure 6.25 Die Protection Bypass Screen

Advertising