August 30, 2002 Manual Version 1.0

4.7

Section 4.2.1 Machine Parameters Menu


Pressing the Machine Parameters softkey in the Main Configuration menu accesses the Machine
Parameters menu, shown in Figure 4.6. This menu is where you will begin the configuration process.














Figure 4.6 Machine Parameters Configuration Menu


Note that some numeric settings may already be programmed when you receive the unit. These
settings were made during the checkout of your unit at the factory and must be reprogrammed as
you configure the system based on the specific characteristics of your press.


Section 4.2.1.1 Configuring the Encoder (Resolver) Type

The first step after you have initially installed the OmniLink II system will be to select the
Encoder Type setting on the Machine Parameters menu.
An encoder is provided with each
OmniLink II Press Automation Control to be driven in a one-to-one ratio by the crankshaft of the press
to supply crankshaft angular position information to the system. The angular position display in the
upper left corner of the screen displays the angle provided by the encoder.

Link offers two different encoders with the OmniLink II Press Automation Control. The standard
encoder is the 2500 Resolver. An optional 5000 Resolver is also offered that combines a resolver and an
optical encoder in the same enclosure to allow cross checking of the angular position information. You
must determine which resolver you ordered with your system and set either “2500” or “5000” as the
Encoder Type setting, the first menu item in the Machine Parameters Menu. This setting will be selected
(highlighted) when the screen first appears. When the Encoder Type setting is selected, pressing the
Change Setting softkey will toggle the setting between “2500” and “5000”. If you have a 2500 resolver
and the setting already appears as 2500 in the highlighted area, you don’t need to push the Change
Setting softkey.

Section 4.2.1.2 Setting Top of Stroke Angle

After setting the Encoder Type, look at the Top of Stroke Angle setting, the third menu item from the

SOFTKEYS
WHEN
ENCODER
OFFSET IS
SELECTED

SO FTKEYS
WHEN
NUMERIC
SETTINGS
SELECTED

CHANGE
N UMBER

EXIT

TOP
STOP

MID
STOP

RESET
FA ULT

SET
ZERO

CHA NGE
NUMBER

EXIT

TOP
STOP

MID
STOP

R ESET
FAULT

Stro ke

Mode

Drive

Speed
Stroke
Speed

SPM

SPM

0
0

Orde r

Counte r

SYSTEM STAT US

Counte r O FF

8

0

OK

Machine

Params

C HANG E
SETTING

EXIT

Encoder Type :

Enco der Offset :

Top of Stroke Angle :

Minimum Press Speed :

Loss of Mot ion Time :

Use Mode Input :

Clutch Engagement Time Limit :

Brake Monit or T op Stop Limit :

Brake Monitor Mid Stroke Stop Limit :

Brake Monitor Actual Stop Time :

Clutch Actual Engagement Time :

2500

0

0

2

20

N o

20

20 0

20 0

15 0

95

0

o

o

msecs

msecs

msecs

msecs

msecs

msecs

SPM

(TOP)

TOP
STOP

MID
STOP

NOTE! The last two items are not settings and a value cannot be entered for
them. They are actu al measured times for stopping and clutch engagement
th at a ppear each tim e the press starts and stops. They are used to de termine
the proper b rake m onitor and clutch engagement ti me limits in the
config uration process as d escribed in the co nfiguration sections for brak e
monitor and clutch engagement ti me .

R ESET
FAULT

Appears only w hen stop limit or clutch engagement time limit
is exceeded

SPEED
CONFIG