August 30, 2002 Manual Version 1.0

4.30

the Access Configuration screen shown in Figure 4.15. The Restrict/Unrestrict configuration screen
shown in Figure 4.16 will be displayed.



















Figure

4.16

Restrict/Unrestrict

Actions Configuration Screen


The actions listed on this screen are those current at the time this manual was written. Later
versions of OmniLink II software may list additional actions to restrict or unrestrict. With the
exception of actions related to Counters, which are standard, the actions listed need to be
configured only if the optional hardware for these functions is used with the system. For example,
if no Tonnage Monitor is used with the system, simply leave the TM Reset setting as “No”.

Select (highlight) the settings for all actions listed on the screen that you wish to be unrestricted and
press the CHANGE SETTING softkey to toggle the setting to “Yes”. Use settings of “No” if you wish
the action to be restricted to Program Mode.

Section 4.2.4.3.3 Setting Access Timeout

If an access mode that uses a code is chosen, you should make Access Timeout settings. A user that
gains access by using his code (password) will be logged in until he manually logs out or is
automatically logged out. See Section 3.9.3. Automatic log out can be either time based or stroke
based. The log out time and the log out number of strokes are programmed in the Access Configuration
menu shown in Figure 4.15.

The timed log out is based upon the time between keyboard activity. If the user does not press any key
on the operator terminal within the time programmed, the control will automatically log out the user. To
program the Access Timeout time move the cursor to Access Timeout time, press the Change Number
softkey, enter the desired time, and press the ENT key. This time can be programmed from 0 to 999
seconds. A timeout time of 0 seconds turns off the timed log out. If the Access Timeout time is set to 0
seconds, there is no time based automatic log out.

Stroke

Mode

Drive

Speed
Stroke
Speed

SPM

SPM

0

0

Order

Counter

SYSTEM STATUS

Counter OFF

8

0

OK

Restrict/
Unrestrict

CHANGE
SETTING

EXIT

The following permissions can be set to allow anyone

access to the actions listed at any time. If “Yes” APPEARS

AFTER THE LISTED ACTION THEN NO PROGRAM KEY OR CODE WILL

BE REQUIRED TO PERFORM THE ACTION! User permissions as set

in the “User Configuration” screen will be overridden by

these settings.

ACTIONS THAT REQUIRE NO KEY OR CODE

TM Reset :

DP Limited Bypass :

DP Reset :

Auto Setup Reset :

Counter Reset :

Counter Settings :

Counter Change :

Motor Speed Adjust :

Yes

No

Yes

No

No

No

Yes

No