Omnilink ii lcd, Operator terminal, Figure 3.1 omnilink ii color lcd operator terminal – LINK Systems OmniLink II Press Automation Control User Manual

Page 34

Advertising
background image

August 30, 2002 Manual Version 1.0

3.1

Section 3 Operator Terminal Basics

Section 3.1 OmniLink II Press Automation Control LCD Operator Terminal

The OmniLink II Operator Terminal features a 9.2” diagonal color TFT liquid crystal display (LCD)
with high brightness and large viewing angle, a keypad, and a Program/Run keyswitch. The large
display allows far more information to be shown on one screen than smaller ¼ VGA LCD displays,
allowing fewer screens to be used to program system settings and view information in a system that has
a multiplicity of functions. Unlike monochrome LCD displays, the color display can be used to call
operator attention to fault or other messages through color highlighting. This, in conjunction with its
softkey driven menu system and help messages provides easy to use operation.






























Figure 3.1 OmniLink II Color LCD Operator Terminal

Figure 3.1 shows the operator terminal front panel with the Main Screen selected on the display. The
color liquid crystal display (LCD) is divided into fixed areas. Crankshaft position and current stroking
mode of the press are displayed in the upper left hand corner of the color LCD screen. This angular
position of press crank or eccentric is displayed in both graphical and numeric format. For speeds less
than sixty strokes per minute, the pointer, which is enclosed in a circle, will rotate to visually indicate
the angular position of the crankshaft. For eccentric and crankshaft driven presses, the top dead center
of the stroke is equal to 0 degrees. The bottom dead center of the stroke is always 180 degrees. In
addition to the rotating pointer, there is a rectangular box enclosed in the circle. When the slide is
stopped within +/- 5 degrees of top, this box will be green with the letters “TOP”. When the slide is

Stroke

Mode

Drive

Speed
Stroke

Speed

SPM

SPM

0
0

Order

Counter

SYSTEM STATUS

Counter:

MAIN
SCREEN

PRESS
CONTROL

AUTO
SETS

TONNAGE
MONITOR

DIE
PROTECTION

LIMIT
SWITCH

JOB
SETUPS

0

0

MOTOR

SPEED

STATUS:
OK

STATUS:
ALL CONDITIONS OKAY

STATUS:
ALL CONDITIONS OKAY

STATUS:
ALL CONDITIONS OKAY

JOB NUM. DESCRIPTION

100000 FRONT BRACKET

COUNTER LIMIT QUANTITY

ORDER

BATCH

SPM

0

% LOAD

161

2000

500

7
7

READY TO STROKE

TOP

COUNTERS

CHG

ACC

CLR

ENT

1

2

3

4

5

6

7

8

9

0

BRAKE

MONITOR

ON

OmniLink II LCD

OPERATOR TERMINAL

LINK ELECTRIC & SAFETY CONTROL CO.

444 McNALLY

DR. NASHVILLE, TN 37211

PHONE (615) 833-4168

OK

PROG RUN

Four user
selected

items

Position

Information

Menu

Reference

Softkeys

Color LCD

Program//Run

Key

Screen Legend

Areas for Softkeys

Softkeys

Keypad

ANALOG
MONITOR

STATUS:
ALL CONDITIONS OKAY

STATUS:
ALL CONDITIONS OKAY