August 30, 2002 Manual Version 1.0

4.26

Continuous mode at various speeds between the low and high speeds. For each speed, press the Top
Stop key and verify that the press stops within a few degrees of top for each speed.

Section 4.2.4 Operator Terminal Configuration


Section 4.2.4.1 Top Area (Screen) Display Configuration

Pressing the OPERATOR TERMINAL softkey on the Main Configuration menu causes the Top
Display Area Configuration Screen shown in Figure 4.13 to be displayed.






















Figure 4.13 Top Display (Screen) Area Configuration.


The OmniLink II LCD Operator Terminal provides for some user customization of the information
displayed in the top areas of the screen to the right of the angle display. When any of the items beside
Area 1, Area 2, etc. at the top of the screen are highlighted pressing the change setting softkey will cause
a box to appear listing all items not already currently assigned to another area. Select the desired
item and press the ENT(ER) key. The currently available items are:

1. Drive Speed. Speed at which a variable speed drive will cause the press to stroke when the clutch is

engaged -- requires optional Analog Input/Output Card for the R/D-Brake Monitor Module

2. Stroking Speed. Actual crankshaft SPM -- available only when the press is actually stroking
3. Auto Press Speed. Drive speed when press is not stroking and crankshaft speed when the press

is stroking-- requires optional Analog Input/Output Card for the R/D-Brake Monitor Module

4. System Status. Diagnostic messages that indicate anything that prevents the start of stroking
5. Reason for the Last Stop. Diagnostic message that gives the reason for the last stop
6. Total Tonnage. If the system is equipped with optional Tonnage & Signature monitor

Stroke

Mode

Drive

Speed
Stroke
Speed

SPM

SPM

0
0

Order

Counter

SYSTEM STATUS

Counter OFF

8

0

OK

Top Disp

Config

CHANGE
SETTING

EXIT

AUXILIARY
COMM SETUP

ACCESS
CONFIG

ZERO
STROKE

COUNT

Top Display Area Configuration

When in a Setup Mode
(Inch, Timed Inch, Etc. )

When in a Production Mode
(Single Stroke, Cont. , Etc. )

Area 1 :

Area 2 :

Area 3 :

Area 4 :

Drive Speed

Stroking Speed

Shut Height

System Status

Area 1 :

Area 2 :

Area 3 :

Area 4 :

Drive Speed

Stroking Speed

Order Counter

System Status

Date :

Time :

4/24/2002

10:20:46 AM

Rod/Stroke Units :

Rod Length :

Stroke Length :

in

0.000 in

0.000 in

Default Language :

English