August 30, 2002 Manual Version 1.0

3.14




















Figure 3.13 Die Protection Channels Settings Program Mode Screen

.
To perform a reset action when a die protection fault occurs with a Code Access Mode, press the
RESET FAULT softkey that appears in either Run or Program Mode on the main Die Protection Screen
shown in Figure 3.9 when the Fault occurs. The popup User Name entry box will appear, allowing a
name to be selected. When the name is selected, the popup User Code box will appear to allow entry of
a code. Entry of a valid code will reset the fault. Note! The condition that creates a die protection
fault must be cleared before a reset can occur.

This access will remain until the user performs a log out or until the user is automatically logged out by
a timeout or limited number of strokes function set in the configuration menu and described in this
section. The user can log out by using the ACC key. This key will directly switch the display to the
Quick Access screen. The LOGOUT soft key legend will appear along the bottom of the screen. If the
operator presses this key, he will log out. He will have to log on again for renewed access to the
restricted items.

Section 3.9.4 Automatic Log Out

In addition to the manual log out, the system contains an automatic logout. The intent of automatic
log out is to reduce the possibility of users other than the intended user from having access to restricted
items. If there were no provisions for automatic log out and a user forgot to manually log out, all
restricted items to which the user had been designated for access would be available from the log in time
until power was removed from the OmniLink II. This presents the possibility of users other than the
intended user having access to restricted items. Automatic log out is based upon both time and press
strokes. During system configuration automatic Access Timeout parameters are entered. Automatic
access timeout time and automatic access timeout strokes can be entered. The time entered is the
amount of time after the last keystroke that will be allowed before the system will automatically log out
the user. For example, if the automatic access timeout is set to 60 seconds, the user will be logged out
60 seconds after the last keystroke. If the user depresses a key before the 60 seconds have elapsed, a

Stroke

Mode

Drive

Speed
Stroke
Speed

SPM

SPM

0

0

Ord er

Counter

SYSTEM STATUS

Counter OFF

DP Chan
Settings

CHANGE
SETTING

CHA NNEL
DIAGS

NEXT
CHA NNEL

0

0

OK

T OP

EXIT

0

90

270

180

Die Prot. Channel Settings

Module: 1 Channel: 5

Channel Type:

Description:

Input Type:

Stop Type:

Bypassed:

Delay Time:

Delay Strokes:

Window On:

Window Off:

C yclic

Left Fr ont Stripper

Normally OFF

Top Sto p

No

0 mse cs

0 Strokes

154

0

213

0

Help

Sets the type of Logic

to apply to the

channel

Cyclic - Norm. OFF

U sed to monitor events that occur

once per m achine cycle. The input

must be ON somewhere in the timing

window AND OFF somewhere in the

timing window.

PREVIOUS
CHA NNEL

DECREMENT
ON ANGLE

IN CREM ENT
ON ANGLE

DECREMENT
OFF ANGLE

IN CREMENT
OFF ANGLE

SoftKeys

CHANGE SETTING,
CHANGE NAME, or
CHANGE NUMBER
in Program Mode
depending on setting
selected.