Softkeys – LINK Systems OmniLink II Press Automation Control User Manual

Page 43

Advertising
background image

August 30, 2002 Manual Version 1.0

3.10



















Figure 3.7 Main Die Protection Screen in Run Mode for Module 1, Channels 1-8





















Figure 3.8 Channel Settings Screen for Module 1, Channel 5

Once Program Mode is entered, the upper right softkey on screens throughout the OmniLink II
Press Automation Control is used in the editing (change) process of any setting selected by use of
the arrow keys on the operator terminal. See Sections 3.7 and 3.8.

In Key Only Access Mode,
the Channel Settings Softkey
will select the DP Channel
Settings screen so settings
can be viewed in Run Mode,
but the Program/Run switch
must be turned to Program
to change settings on the
DP Channel Settings screen.

Stroke

Mode

Drive

Spe ed
Stroke
Spe ed

SPM

SPM

0

0

Order

Counter

SYSTEM STATUS

Counter OFF

Die

Protection

CHANNEL

SETTINGS

CHANNEL

DIAGS

NEXT

PAGE

0

0

OK

TO P

EXIT

Ch Channel Type

Description

Status

State

1 S tatic

Stock Buckle

OK

Off

2 Not Used

OK

Off

3 1 Part Dete ctor Edge

Par t Ou t

OK

Off

4 In Position

Die Cam Retracted

OK

On

5 Cyclic

Stripp er Left Front

OK

Off

6 Cyclic

Stripp er Right Fron t

OK

Off

7 Cyclic

Stripp er Left Rear

OK

Off

8 Cyclic

Stripp er Right Rear

OK

Off

Module 1 - Channe l 5 Details

Input Type:

Stop Typ e:

Bypassed:

Delay Time:

Delay Strok es:

Window On:

Window Off:

Nor mally OFF
Top S top
No
0 msecs
0 S trokes
154

0

213

0

0

90

270

180

Channel

Status

OK

System Status: OK

Module Status: OK

SoftKeys

5

RESET
FAULT

Appears only with
Program/Run switch
in Program Position.

Stroke

Mode

Drive

Speed
Stroke
Speed

SPM

SPM

0

0

Order

Counter

SYSTEM STATUS

Counter OFF

DP Chan
Settings

CHANGE
SETTING

CHA NNEL
DIAGS

NEXT
CHA NNEL

0

0

OK

T OP

EXIT

0

90

270

180

Die Prot. Channel Settings

Module: 1 Channel: 5

Channel Type:

Description:

Input Type:

Stop Type:

Bypassed:

Delay Time:

Delay Strokes:

Window On:

Window Off:

C yclic

Left Fr ont Stripper

Normally OFF

Top Sto p

No

0 mse cs

0 Strokes

154

0

213

0

Help

Sets the type of Logic

to apply to the

channel

Cyclic - Norm. OFF

U sed to monitor events that occur

once per m achine cycle. The input

must be ON somewhere in the timing

window AND OFF somewhere in the

timing window.

PREVIOUS
CHA NNEL

DECREMENT
ON ANGLE

IN CREM ENT
ON ANGLE

DECREMENT
OFF ANGLE

IN CREMENT
OFF ANGLE

SoftKeys

CHANGE SETTING,
CHANGE NAME, or
CHANGE NUMBER
in Program Mode
depending on setting
selected.

Advertising