LINK Systems OmniLink II Press Automation Control User Manual

Page 39

Advertising
background image

August 30, 2002 Manual Version 1.0

3.6




















Figure 3.3 The Die Protection Channel Settings Screen in Program Mode

When the Channel Type setting is selected, the upper right softkey legend is CHANGE SETTING.
Pressing the CHANGE SETTING softkey will cause a list box to appear as on the screen as shown
in Figure 3.4, and the upper right softkey legend will change to SELECT. The arrow keys are used
to highlight the desired item on the list after which the SELECT softkey is pressed to enter the
selected item and remove the list box.










Figure 3.4 List Box for Die Protection Type and SELECT Softkey


2. A CHANGE NAME softkey will appear on the screen when a description or name setting is

selected. In some cases, a screen showing a list of default names or descriptions commonly used for
the setting will appear when this softkey is pressed, allowing selection of a name or description to
enter by pressing a SELECT softkey that appears for this type of setting. In addition, you may edit
(change) existing or unnamed items on the list by selecting the item and pressing an EDIT NAME
softkey on the screen after your selection. In this case, another popup menu, the Text Entry menu,
will appear that allows you to enter letters, numbers, and spaces for the name or description selected.
This also can be illustrated by use of the Die Protection Channel Settings screen. If the setting for
Description is selected, the upper right softkey legend will be CHANGE NAME. Pressing this key
causes the Die Protection Names screen to appear as shown in figure 3.5

Stroke

Mode

Drive

Speed
Stroke
Speed

SPM

SPM

0

0

Order

Counter

SYSTEM STATUS

Counter OFF

DP Chan
Settings

CHANGE
SETTING

CHA NNEL
DIAGS

NEXT
CHA NNEL

0

0

OK

T OP

EXIT

0

90

270

180

Die Prot. Channel Settings

Module: 1 Channel: 5

Channel Type:

Description:

Input Type:

Stop Type:

Bypassed:

Delay Time:

Delay Strokes:

Window On:

Window Off:

C yclic

Left Fr ont Stripper

Normally OFF

Top Sto p

No

0 mse cs

0 Strokes

154

0

213

0

Help

Sets the type of Logic

to apply to the

channel

Cyclic - Norm. OFF

U sed to monitor events that occur

once per m achine cycle. The input

must be ON somewhere in the timing

window AND OFF somewhere in the

timing window.

PREVIOUS
CHA NNEL

DECREMENT
ON ANGLE

IN CREM ENT
ON ANGLE

DECREMENT
OFF ANGLE

IN CREMENT
OFF ANGLE

SoftKeys

CHANGE SETTING,
CHANGE NAME, or
CHANGE NUMBER
in Program Mode
depending on setting
selected.

Not Used
Static
Cyclic

Transfer

In Position
1 Part Detector Edge
1 Part Detector Pass
2 Part Detector Edge
2 Part Detector Pass
Custom

SELECT

Legend for upper right softkey

Advertising