ERROR CODES

___________________________________________________________________

Error No.

Message / Action

10-5

041

Failure of Communications.

This error indicates that the Operator Interface
Terminal cannot communicate with the Logic Unit.

1)

Check the communication cable connecting
terminals A, B, and C of the Operator Interface
terminal to the Logic Unit.

2)

Check that the power supply connectors on the
Operator Interface Terminal and the Logic Unit
are properly connected.

042

Internal Error. Call Factory.

1)

Notify Link Systems of this error.

043

Internal Error. Call Factory.

1)

Notify Link Systems of this error.

044

Invalid job data detected.

This error occurs when the System 1100 Tonnage
Monitor encounters an error when using the machine
rating in tonnage setpoint scaling calculations.
This error is usually caused by inadvertently
changing the machine rating setting in the config
menu. This error can also result from a memory
failure causing a setpoint to assume an improper
value.

1)

Check the MACH RATING setting in the config menu
for proper setting.

2)

Check all setpoints (high, low, and reverse for
the peak and all data windows) for correctness.

045

Current job setup corrupt.