INSTALLATION

___________________________________________________________________

5-12

clutch mechanism, the point in the stroke where the overload
occurs, and the machine speed determine whether the machine can
stop quickly enough after an overload is sensed to avoid the peak
overload. One consequence of connecting the System 1100 into the
emergency stop circuit can be sticking the machine on bottom when
an overload occurs.