ERROR CODES

___________________________________________________________________

Error No.

Message / Action

10-7

048

Channel 1 high setpoint too high.

049

Channel 2 high setpoint too high.

050

Channel 3 high setpoint too high.

051

Channel 4 high setpoint too high.

The Peak tonnage high setpoint of the channel
indicated by the error code is set to a value
greater than 125% of the channel rating.

1)

Check the MACH RATING setting in the Config menu
for correctness.

2)

Adjust the indicated setpoint to a setting less
than 125% of the channel rating.

052

Channel 1 low setpoint too high.

053

Channel 2 low setpoint too high.

054

Channel 3 low setpoint too high.

055

Channel 4 low setpoint too high.

The Peak tonnage low setpoint of the channel
indicated by the error code is set to a value
greater than 125% of the channel rating.

1)

Check the MACH RATING setting in the Config menu
for correctness.

2)

Adjust the indicated setpoint to a setting less
than 125% of the channel rating.

056

Channel 1 reverse setpoint too high.

057

Channel 2 reverse setpoint too high.

058

Channel 3 reverse setpoint too high.

059

Channel 4 reverse setpoint too high.

The Peak tonnage reverse setpoint of the channel
indicated by the error code is set to a value
greater than 125% of the channel rating.

1)

Check the MACH RATING setting in the Config menu
for correctness.

2)

Adjust the indicated setpoint to a setting less