LINK Systems System 1100 Tonnage Monitor User Manual

Page 116

Advertising
background image

ERROR CODES

___________________________________________________________________

Error No.

Message / Action

10-13

117

Data window 4, channel 2 low setpoint too high.

118

Data window 4, channel 3 low setpoint too high.

119

Data window 4, channel 4 low setpoint too high.

The Data window 4 low setpoint of the channel
indicated by the error code is set to a value
greater than 125% of the channel rating.

1)

Check the MACH RATING setting in the Config menu
for correctness.

2)

Adjust the indicated setpoint to a setting less
than 125% of the channel rating.

120

Data window 4, channel 1 reverse setpoint too high.

121

Data window 4, channel 2 reverse setpoint too high.

122

Data window 4, channel 3 reverse setpoint too high.

123

Data window 4, channel 4 reverse setpoint too high.

The Data window 4 reverse setpoint of the channel
indicated by the error code is set to a value
greater than 125% of the channel rating.

1)

Check the MACH RATING setting in the Config menu
for correctness.

2)

Adjust the indicated setpoint to a setting less
than 125% of the channel rating.

124

Data window 4, chan 1 high setpoint < low setpoint.

125

Data window 4, chan 2 high setpoint < low setpoint.

126

Data window 4, chan 3 high setpoint < low setpoint.

127

Data window 4, chan 4 high setpoint < low setpoint.

The Data window 4 high setpoint of the channel
indicated by the error code is set to a value less
than the low setpoint.

1)

Adjust the high or low setpoint so that the high