Rocktron All Access User Manual

Page 15

Advertising
background image

12

SETUP, Page 2 of 10 - Bank Size

The second page of the SETUP program allows for the selection of the Bank

Size, or the number of presets that the All Access™ will bank up or down by when

the UP or DOWN switches are pressed.

When set to "5", switches 1-5 become preset switches and the unit will bank

up or down by 5 presets at a time. When set to "10", switches 1-10 become preset

switches and the unit will bank up or down by 10 presets at a time. When set to "15",

switches 1-15 become preset switches and the unit banks up or down by 15 presets

at a time. When set to "1", the unit banks up or down by one preset at a time and

all of the switches become instant access switches.

The Bank Size setting also determines the number of preset switches for

each song when operating the All Access™ in Song mode.

About Preset and Instant Access Switches:

The All Access™ can be configured so that one row (switches 1-5), two

rows (switches 1-10) or three rows (switches 1-15) of switches can be dedicated as

preset switches, or switches that are used to select the various presets within each

bank. Preset switches send out commands which can reconfigure a whole rack.

Any switches that are not configured as preset switches automatically

become instant access switches - or switches that are used to send specific MIDI

controller information on specific MIDI channels. Instant access switches are used

to switch in or out a specific effect or function on a MIDI receiving device - thereby

giving the user direct control over that specific effect or function without affecting

other effects, functions or presets within a rack of devices.

Instant access switches can operate globally or per preset (see Setup, Page

4), and each can be configured to operate as a latching, momentary or hold type

switch. (To configure instant access switches, refer to MIDI, Pages 2-4.)

To Select the Bank Size:

(Œ) With the All Access™ still in SETUP mode (2ND and SETUP L.E.D.s lit), press

the "ð" switch to access the second page of the SETUP program, Bank Size.

(If the All Access™ is not already in SETUP mode, press "2ND", then

"SETUP", followed by "ð" one time.)

() To select a new bank size, press the "INC" or "DEC" switches directly below

the currently selected option to scroll through the available selections.