The SYSX program allows the user to perform a bulk dump or bulk load of

the entire All Access™ programmable memory, as well as create a system exclusive

MIDI string up to 30 bytes long for each preset to communicate device and

manufacturer specific information.

SYSX, Page 1 of 3 - Bulk Dump/Load

The first page of the SYSX program, Bulk Dump/Load, allows for the user

to perform a Bulk Dump or Load of the All Access™ programmable memory.

To access the SYSX program:

(Œ) To access SYSX, press the "2ND" button to activate the secondary button

functions.

() Press the "SYSX" button. The L.E.D. above the "SYSX" button will flash and the

All Access™ will display the first page of the SYSX program.

To perform a bulk dump or load:

(Ž) Use the "INC" and "DEC" switches directly below the current dump/load

status displayed to select whether a Bulk Dump or Bulk Load is to be

performed.

*If a Bulk Load is to be performed, the All Access™ must display this editing

page and "LOAD" must be selected for the All Access™ to receive a Bulk

Dump from another device.

() If a Bulk Dump is to be performed, press the "CTR STORE" button to initiate

the dump.

SYSX

­

When receiving a Bulk Load, it is important that the data loaded to the
All Access™ is not transmitted faster than it was originally dumped
from the All Access™. If information is sent too fast to the All Access™,
a "Buffer Overflow" error will occur.

When dumping information from a data storage device, such as an
Alesis Data Disk, it is necessary to perform the dump in

sequence

mode rather than

sysx mode. Sequence mode will dump the information

back to the All Access™ at the same speed as it was received from the
All Access™. The All Access™ can receive a data dump at about 65Hz
(or about 1 byte every 15 milliseconds).