Turn the PARAMETER ADJUST control to scroll through the available parameters for the
current configuration.

PARA1

XXX

Step 5

Turning the PARAMETER SELECT control one step clockwise will display the effect param-
eter that is currently mapped to the NUMB1 control number.

PARA1 EFFECTS LVL

Step 6

After selecting the parameter to be assigned to the NUMB1 controller, press the STORE button
to save it. "STORED" will flash briefly on the display.

Step 7

STORED

Turn the PARAMETER SELECT control to display the next parameter - "Controller Upper
Limit".

Step 8

ULIM C1

XXX

Use the PARAMETER ADJUST control to select the highest parameter value that the controller
is not to exceed.

Step 9

ULIM C1

+2.5

Step 10

After selecting the value for the upper limit, press the STORE button to save it. "STORED" will
again flash briefly on the display.

STORED

The Intellipitch allows for the range of any given parameter to be limited when using a MIDI
controller to determine the current parameter value. For example, if a given parameter has a
range from -

to +6dB yet it is desirable for the full range of the controller to vary from only -

10dB to +2.5dB, a lower limit of -10 and an upper limit of +2.5 may be set via the "Upper
Limit" and "Lower Limit" parameters. When storing a parameter, the maximum value is stored
as the upper limit and the minimum value is stored as the lower limit automatically.